Record Details

DESAIN ULANG SISTEM PEMBANGKIT TEKANAN PADA MESIN HYDROTEST GUNA MENCAPAI STANDAR PENGUJIAN TEKANAN ASTM A53 UNTUK PIPA 3 INCH

G-Tech: Jurnal Teknologi Terapan

View Archive Info
 
 
Field Value
 
Title DESAIN ULANG SISTEM PEMBANGKIT TEKANAN PADA MESIN HYDROTEST GUNA MENCAPAI STANDAR PENGUJIAN TEKANAN ASTM A53 UNTUK PIPA 3 INCH
 
Creator Hidayatulloh, Arif
Choifin, Mochamad
 
Description Mesin hydrotest adalah mesin digunakan untuk menguji kekuatan dan kebocoran pipa dimana pengujian ini penting untuk menjamin kualitas pipa. Pengujian ini bekerja dengan mengisi komponen pipa uji dengan cairan danĀ  menekannya, kemudian ditahan pada jumlah waktu tertentu untuk pemeriksaan indikasiĀ  kebocoran pada pipa uji tersebut. Terdapat Mesin hydrotest yang khusus untuk pengujian pipa diameter 3 inch, data yang di dapat dari penelitian mesin mampu menghasilkan tekanan maksimal sebesar 63,7 bar tekanan ini masih mampu mencapai standar SNI 0039 dengan tebal 3,2 mm yang mensyaratkan minimal pengujian tekanan sebesar 50 bar, untuk meningkatkan standar mutu uji menurut standar ASTM A53 untuk pipa 3 inch dengan ketebalan 5,49 yang mensyaratkan maksimal tekanan uji sebesar 173 bar, data cycle time pengujian mulai dari pengisian cairan, proses penekanan hingga selesai di dapat waktu selama 35 detik. Tujuan dari penelitian ini adalah untuk mendapatkan desain mesin hydrotest yang memiliki unjuk kerja lebih optimal dan sesuai standar ASTM A53. Tahapan dalam perencanaan ini adalah studi literatur yang berhubungan dengan teori tekanan hidrostatik, melakukan observasi terhadap mesin hydrotest, melakuakan analisis desain lama, perencanaan ulang sistem hidrolik (intensifier) sebagai pembangkit tekanan tinggi dan penyesuaian desain dengan parameter yang direkomondasikan.
Hydrotest machine is a machine used to test the strength and leakage of a pipe where this test is important to guarantee the quality of the pipe. This test works by filling the test pipe components with liquid and pressing it, then held for a certain amount of time to check for indication of leakage in the test pipe. There is a hydrotest machine specifically for testing 3 inch diameter pipes, the data obtained from machine research is able to produce a maximum pressure of 63.7 bar. This pressure is still able to reach the SNI 0039 standard with a thickness of 3.2 mm which requires a minimum testing pressure of 50 bar , to improve the test quality standards according to ASTM A53 standards for 3-inch pipes with a thickness of 5.49 which requires a maximum test pressure of 173 bar, cycle time test data starting from liquid filling, pressing process until completion in 35 seconds. The purpose of this study is to obtain a hydrotest engine design that has a more optimal performance and complies with ASTM A53 standards. The stages in this plan are the study of literature relating to the theory of hydrostatic pressure, making observations of hydrotest machines, carrying out old design analysis, re-planning the hydraulic system (intensifier) as a high pressure generator and adjusting the design to the recommended parameters.
 
Publisher Universitas Islam Raden Rahmat Malang
 
Date 2020-09-02
 
Type info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Artikel Peer-review
 
Format application/pdf
 
Identifier https://ejournal.uniramalang.ac.id/index.php/g-tech/article/view/336
10.33379/gtech.v2i2.336
 
Source G-Tech: Jurnal Teknologi Terapan; Vol. 2 No. 2 (2019): G-Tech April 2019; 145-152
G-Tech: Jurnal Teknologi Terapan; Vol 2 No 2 (2019): G-Tech April 2019; 145-152
2623-064X
2580-8737
10.33379/gtech.v2i2
 
Language ind
 
Relation https://ejournal.uniramalang.ac.id/index.php/g-tech/article/view/336/366
 
Rights Hak Cipta (c) 2019 G-Tech : Jurnal Teknologi Terapan
https://creativecommons.org/licenses/by/4.0